美国医用超声协会超声探头消毒指南

本文由用户“静是我啦”分享发布 更新时间:2020-07-25 09:34:49 举报文档

以下为《美国医用超声协会超声探头消毒指南》的无排版文字预览,完整格式请下载

下载前请仔细阅读文字预览以及下方图片预览。图片预览是什么样的,下载的文档就是什么样的。

Guidelines for Cleaning and Preparing External- and Internal-Use Ultrasound Probes Between Patients, Safe Handling, and Use of Ultrasound Coupling Gel Section I: Ultrasound Probe Cleaning and Preparation The purpose of the first section of this document is to provide guidance regarding the cleaning and preparation of external and internal ultrasound probes. Some manufacturers use the term “transducers” or “imaging arrays.” Medical instruments fall into different categories with respect to their potential for pathogen transmission. The most critical instruments are those that are intended to penetrate skin or mucous membranes. These require sterilization. Less critical instruments (often called “semicritical” instruments) that simply come into contact with mucous membranes, such as fiber-optic endoscopes, require high-level disinfection rather than sterilization. “Noncritical” devices come into contact with intact skin but not mucous membranes. External probes that only come into contact with clean, intact skin are considered noncritical devices and require cleaning after every use as described below. All internal probes should be covered with a single-use barrier. If condoms are used as barriers, they should be nonlubricated and nonmedicated. Although internal ultrasound probes are routinely protected by single-use disposable probe covers, leakage rates of 0.9% to 2% for condoms and 8% to 81% for commercial probe covers have been observed in recent studies (Rutala and Weber, 2011). These probes are therefore classified as semicritical devices. Note: Practitioners should be aware that condoms have been shown to be less prone to leakage than commercial probe covers and have a 6-fold enhanced acceptable quality level (AQL) when compared to standard examination gloves. They have an AQL equal to that of surgical gloves. Users should be aware of latex sensitivity issues and have non–latex-containing barriers available. For maximum safety, one should therefore perform high-level disinfection of the probe between each use and use a probe cover or condom as an aid to keep the probe clean.For the purpose of this document, "internal probes" refers to all vaginal, rectal, and transesophageal probes, as well as intraoperative probes and all probes that are in contact with bodily fluids/blood or have a remote chance to be in contact with dry/cracked skin and body fluids, including blood. Definitions All cleaning, disinfection, and sterilization represent a statistical reduction in the number of microbes present on a surface rather than their complete elimination. Meticulous cleaning of the instrument is the key to an initial reduction of the microbial/organic load by at least 99%. This cleaning is followed by a disinfecting procedure to ensure a high degree of protection from infectious disease transmission, even if a disposable barrier covers the instrument during use. According to the Centers for Disease Control and Prevention (CDC) Guideline for Disinfection and Sterilization in Healthcare Facilities (2008): "Cleaning is the removal of visible soil (eg, organic and inorganic material) from objects and surfaces and normally is accomplished manually or mechanically using water with detergents or enzymatic products. Thorough cleaning is essential before high-level disinfection and sterilization because inorganic and organic material that remains on the surfaces of instruments interfere with the effectiveness of these processes." "Disinfection describes a process that eliminates many or all pathogenic microorganisms, except bacterial spores." Low-Level Disinfection—Destruction of most bacteria, some viruses, and some fungi. Low-level disinfection will not necessarily inactivate Mycobacterium tuberculosis or bacterial spores. Mid-Level Disinfection—Inactivation of M Tuberculosis, bacteria, most viruses, most fungi, and some bacterial spores. High-Level Disinfection—Destruction/removal of all microorganisms except bacterial spores. “Sterilization describes a process that destroys or eliminates all forms of microbial life and is carried out in healthcare facilities by physical or chemical methods. Steam under pressure, dry heat, ethylene oxide (EtO) gas, hydrogen peroxide gas plasma, and liquid chemicals are the principal sterilizing agents used in health-care facilities . . . . When chemicals are used to destroy all forms of microbiologic life, they can be called chemical sterilants. These same germicides used for shorter exposure periods also can be part of the disinfection process (ie, high-level disinfection).” The following specific recommendations are made for the cleaning and preparation of all ultrasound probes. Users should also review the Centers for Disease Control and Prevention document on sterilization and disinfection of medical devices to be certain that their procedures conform to the CDC principles for disinfection of patient care equipment. 1. Cleaning—Probes should be cleaned after each examination with soap and water or quaternary ammonium (a low-level disinfectant) sprays or wipes. The probes must be disconnected from the ultrasound scanner for anything more than wiping or spray cleaning. After removal of the probe cover (when applicable), use running water to remove any residual gel or debris from the probe. Use a damp gauze pad or other soft cloth and a small amount of mild nonabrasive liquid soap (household dish-washing liquid is ideal) to thoroughly cleanse the probe. Consider the use of a small brush, especially for crevices and areas of angulation, depending on the design of the particular probe. Rinse the probe thoroughly with running water, and then dry the probe with a soft cloth or paper towel. 2. Disinfection—As noted above, all internal probes (eg, vaginal, rectal, and transesophageal probes) as well as intraoperative probes require high-level disinfection before they can be used on another patient. For the protection of the patient and the health care worker, all internal examinations should be performed with the operator properly gloved throughout the procedure. As the probe cover is removed, care should be taken not to contaminate the probe with secretions from the patient. At the completion of the procedure, hands should be thoroughly washed with soap and water. Gloves should be used to remove the probe cover and to clean the probe as described above. Note: An obvious disruption in condom integrity does not require modification of this protocol. Because of the potential disruption of the barrier sheath, high-level disinfection with chemical agents is necessary. The following guidelines take into account possible probe contamination due to a disruption in the barrier sheath. After removal of the probe cover, clean the transducer as described above. Cleaning with a detergent/water solution as described above is important as the first step in proper disinfection, since chemical disinfectants act more rapidly on clean and dry surfaces. Wet surfaces dilute the disinfectant. High-level liquid disinfection is required to ensure further statistical reduction in the microbial load. Examples of such high-level disinfectants are listed in Table 1. A complete list of US Food and Drug Administration (FDA)-cleared liquid sterilants and high-level disinfectants is available athttp://doc.001pp.com/MedicalDevices/Safety/AlertsandNotices/ucm194429.htm, and other agents are under investigation. To achieve high-level disinfection, the practice must meet or exceed the listed "HighLevel Disinfectant Contact Conditions" specified for each product. Users should be aware that not all approved disinfectants on this list are safe for all ultrasound probes. The CDC recommends environmental infection control in the case of Clostridium difficile, consisting of "meticulous cleaning followed by disinfection using hypochlorite-based germicides as appropriate" (CDC, 2008). The current introduction and initial marketing of a hydrogen peroxide nanodroplet emulsi 内容过长,仅展示头部和尾部部分文字预览,全文请查看图片预览。 minders/2012/pdf/ClinicalReminder_UltraSoundGel_04_20_2012.pdf. 5. Health Canada. Serious risk of infection from ultrasound and medical gels – revision. Health Canada website; December 14, 2004. Accessed April 25, 2016, at http://www.healthycanadians.gc.ca/recall-alert-rappel-avis/hc-sc/2004/14289a-eng.php. Approved 5/16/2017 © American Institute of Ultrasound in Medicine 14750 Sweitzer Lane, Suite 100 ·Laurel, MD 20707-5906 USA Phone: *** ·Fax: *** ·Website: doc.001pp.com [文章尾部最后500字内容到此结束,中间部分内容请查看底下的图片预览]

以上为《美国医用超声协会超声探头消毒指南》的无排版文字预览,完整格式请下载

下载前请仔细阅读上面文字预览以及下方图片预览。图片预览是什么样的,下载的文档就是什么样的。

图片预览